This page describes the setup procedures for the HamPi which is saved in EEPROM memory on the CPU Board. Once a HamPi is set up it should not need to be done again in it's lifetime.
Setup is done from the Front Panel Keypad and it is not necessary to have a computer plugged into the USP port.
These are the various Setup Procedures described on this page:
Factory Reset.
Calibration / setting of the VFO / BFO calibration or SSB / CW Crystal frequencies.
Restart.
Setting the Base IF Frequency.
Calibration Mode
Before any of the calibration settings in EEPROM can be done a normally hidden menu for Calibration must be entered. Normally the Func button is a rotary menu with 4 possible choices. When Calibration Mode is enabled a number of extra calibration options become available. To enter Calibration mode follow these steps:
Press the Func (Functions) button until 'Calibration: Off" is displayed on the bottom line of the TFT
Press the Set button, 'Cal? Press again... Off'
Press the Set button again and '!!! Calibration On' will be displayed. Note it is a bit hard to enter the calibration mode. This is done intentionally.
Calibration of the VFO Clock Crystal Frequency
This sets in permanent memory the frequency offset of the VFO Oscillator / clock.
Use the frequency counter and measure the VFO signal at TP18 (VFO) near J6 on the Radio Board.
Follow these instructions carefully and do not press any other radio buttons or the procedure will fail.
Enter the ‘Calibration On’ mode again, and press the FUNC (Function) button until ‘VFO Calibration’ is displayed.
Press the ‘Set’ button and observe the frequency on the frequency will display close to 10MHz.
Now adjust this frequency up or down until the frequency shows exactly 10MHz (10.000,000Hz)
Once this is done press the SET button once again. This will save the VFO calibration in EEPROM (permanent memory) so that at power up the calibration is recovered. This procedure should never need to be redone.
Calibration of the BFO Clock Crystal Frequency
This procedure is exactly similar as that above for the VFO Calibration.
Press the FUNC (Function) button until ‘BFO Calibration’ is displayed. (Re enter the ‘Calibration On’ mode again if necessary).
Do the same procedure as above but using measuring the frequency at point TP3 BFO. (If the signal level at TP3 does not work (it is a low level signal) on the ISS 9 Radio Board, then carefully probe for the BFO signal on either side of C146 which is located close to U14 (Si5351). On later issue boards there will be a now test point)
Once this is done press the SET button once again. This will save the VFO calibration in EEPROM (permanent memory) so that at power up the calibration is recovered. This procedure should never need to be redone.
Programming the SSB IF Frequency
Notes: At this stage you should have already have either purchased or built and tested a crystal filter board and the SSB & CW IF frequencies are known.
Press the FUNC (Function) button until ‘SSB IF=’ is displayed. (Re enter the ‘Calibration On’ mode again if necessary).
Adjust the main Dial to select the frequency of the SSB Crystal Filter centre frequency. The resolution is 50Hz. An example will be 7998150 on the display.
Next, Press the ‘Set’ button. This will save this filter centre frequency in EEPROM.
Calibration the CW IF Frequency
Press the FUNC (Function) button until ‘CWIF=’ is displayed. (Re enter the ‘Calibration On’ mode again if necessary).
Adjust the main Dial to select the frequency of the CW Crystal Filter centre frequency. The resolution is 50Hz. An example will be 7998650 on the display.
Next, Press the ‘Set’ button. This will save this filter centre frequency in EEPROM.
Restarting the CPU to use programmed settings
Since the above for settings were saved into EEPROM using the Set key these settings will not be lost. A CPU restart is needed however to get the HamPi firmware to read and use these settings. This can be achieved by either powering down the HamPi / CPU Board or following the steps below:
Press the FUNC button one more time and ‘Restart CPU? (Set)’ will be displayed.
Press Set and the HamPiRadio will do a firmware reset. This will set up all the functionality ready for use.
Congratulations! The Radio and CPU board are not calibrated for each other and ready for the next construction phases. These two boards are now a pair, meaning the calibration settings in permanent memory (EEPROM) on the CPU board match those of the crystals and filters on the Radio Board.
If ever the Radio or CPU boards are changed, this calibration procedure must be done again from the beginning. If all has been done successfully, it should never need to be done again.